5. SERVICE PROGRAMME ROYAL
Page 10/24 REV.4 SEPT.2003 Saeco International Group
3.2. Diagnosis menu (Royal Professional Instant Steam / Cappuccino / Cappuccino Redesign)
The values below can be read and adjusted in the diagnosis menu as shown in the table.
Access: The following button combinations can be used in standby mode to access the diagnosis
menu as indicated in the table below. (press menu buttons briefly)
TYPE
Press simultaneously
Whilst pressing
Prof. / Cappuccino
EXPRESSO LUNGO
EXPRESSO
HOT WATER
STANDBY
Cappuccino Redes.
EXPRESSO LUNGO
Powder coffee
EXPRESSO
MENU
(The user programme is also available in this mode.)
Using the button scroll to the menu item "Diagnosis" and confirm via the ENTER button.
Changing programme values: Access appropriate item using the ENTER button.
Change value with ARROW buttons
Save value by using the ENTER button.
Programme table (diagnosis menu):
Function/Standard
Setting range
Increment
Comments
EXPRESSO LUNGO
No. of PULSES 600
50 – 1,000 Pulses
+/- 1
EXPRESSO
No. of PULSES 195
50 – 1,000 Pulses
+/- 1
COFFEE
No. of PULSES 360
50 – 1,000 Pulses
+/- 1
HOT WATER
No. of PULSES 360
50 – 1,000 Pulses
+/- 1
Number of flow meter pulses for
each saved cup fill volume, where
300 pulses correspond to approx.
100 ml.
CAPPUCCINO TIME
SEC. 7
240 +/- 1 The time for cappuccino
dispensing is saved under this item
(cup filling volume).
----HEATING----
PARAMETER K1 7
1 – 50
+/- 1
Do not change!
----HEATING----
PARAMETER K2 30
New processor 40
From 2003 version
1 – 50
+/- 1
Do not change!
----HEATING----
SENSOR ADJUST.
96
From 2003 version
86 – 106
To adjust processor tolerances.
If the temperature in test mode
with a set measuring resistance of
3246 exceeds or falls short of the
specified temperature value (96°C)
by more than 1°C, the value
indicated in test mode must be
applied to adjust the sensor.
No measuring resistance: Do not
change!